Table 10. Permeability and porosity values from cross-hole air-injection testing using borehole NDR-MF#3 for injection and borehole NDR-MF#2 for monitoring [Permeability values are x 10-12 meter squared; porosity is in parentheses; --, no data; FZ, fault zone; PFZ, partial fault zone, defined as a monitor interval located in the fault zone and footwall]
| Permeability and porosity values from monitor intervals located in borehole NDR-MF#2 | ||||||||||||
| Hanging wall | FZ | PFZ | Footwall | |||||||||
Test |
Injection |
Injection |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
|
12 |
26.4-34.3 |
Hanging wall |
7.5 |
5.3 |
4.9 |
12.8 |
-- |
-- |
-- |
-- |
-- |
-- |
16 |
12.3-17.3 |
Fault zone |
-- |
-- |
-- |
20.0 |
10.4 |
6.6 |
11.5 |
13.3 |
-- |
-- |
17 |
3.5-8.5 |
Footwall |
-- |
-- |
-- |
-- |
-- |
12.0 |
5.4 |
5.5 |
5.3 |
-- |
19 |
24.5-26.5 |
Hanging wall |
8.0 |
5.9 |
2.7 |
7.4 |
13.2 |
-- |
-- |
-- |
-- |
-- |
21 |
18.5-20.5 |
Hanging wall |
8.0 |
6.0 |
4.2 |
-- |
3.3 |
20.0 |
-- |
-- |
-- |
-- |
22 |
8.7-10.7 |
Footwall |
-- |
-- |
-- |
-- |
12.7 |
8.4 |
5.2 |
6.3 |
6.9 |
-- |
23 |
3.2-5.2 |
Footwall |
-- |
-- |
-- |
-- |
-- |
13.3 |
8.2 |
7.9 |
7.7 |
34.1 |