Return to the Main Document

Table 12. Permeability and porosity values from cross-hole air-injection testing using borehole NDR-MF#1 for injection and borehole NDR-MF#2 for monitoring [Permeability values are x 10-12 meter squared; porosity is in parentheses; --, no data; FZ, fault zone; PFZ, partial fault zone, defined as a monitor interval located in the fault zone and footwall]

 Permeability and porosity values from monitor
intervals located in borehole NDR-MF#2
  Hanging wall FZ PFZ Footwall

Test
number

Injection
interval depth
(meters)

Injection
interval
structural unit

11

12

13

14

15

16

17

18

19

20

25 25.8-27.8 Hanging wall 5.8

(.04)
4.0

(.04)
2.2

(.01)
6.1

(.03)
17.2

(.10)
--

--
--

--
--

--
--

--
--

--
32 13.3-15.3 Fault zone --

--
--

--
--

--
20.8

(.19)
37.9

(.27)
27.3

(.08)
11.5

(.06)
15.7

(.06)
16.5

(.06)
--

--
36 5.5-7.5 Footwall --

--
--

--
--

--
--

--
23.6

(.16)
11.7

(.06)
9.6

(.04)
8.8

(.04)
9.3

(.04)
--

--

Previous Table | Next Table