Return to the Main Document

Table 15. Input parameters of the six fracture sets used to produce the FRACMAN discrete-features model

[--, not applicable]

 Orientation Size

Fracture
set

Model
Type

Strike/dip
(degrees)

Pole orientation
Trend/plunge
(degrees)

Distribution
type

Dispersion
(k)

Equivalent
radius
(meters)

Distribution
type

Mean / SD
(meters)

Max / Min
(meters)

Intensity
(m2/m3 )

1

Baecher

059/88

329/02

Fisher

50

--

Truncated
Lognormal

0.614/0.27

0.3/150.0

0.17

2

Baecher

075/84

345/06

Fisher

35

--

Truncated
Lognormal

0.62/1.8

0.3/150.0

0.22

3

Baecher

125/84

035/06

Fisher

25

--

Truncated
Lognormal

0.97/2.06

0.3/150.0

2.07

4

Baecher

332/63

242/27

Fisher

25

--

Truncated
Lognormal

0.56/0.8

0.3/150.0

0.08

5

Baecher

192/87

099/03

Fisher

36

0.277

Truncated
Power Law

2.5

0.3/150.0

2.56

6

Baecher

199/63

109/27

Fisher

20

--

Truncated
Exponential

0.54

0.3/150.0

0.11

Previous Table | Next Table